Featuers
Operating pressure |
0 - 400 bar |
Usage rate |
≤ 420 l/min |
Head rotation speeds (Nt) |
15 (1) min-1 |
Nozzle rotation speed (Nb) |
2 (1) min-1 |
Diameter of the swept sphere |
See table bellow |
Maximum fluid temperature |
90 °C |
Number of nozzles |
2 |
Minimum passage diameter |
240 (2) mm |
Weight |
60 Kg |
Dimensions |
240 x 218 x H 780 |
Optimal scanning diameter (m) (4) |
Head inlet pressure (bar) |
100 |
200 |
300 |
400 |
Flow
total
(l/min) |
5,5 |
3,6 |
5,0 |
6,2 |
7,1 |
7,0 |
6,0 |
8,5 |
10,4 |
12,0 |
8,5 |
8,6 |
12,2 |
15,0 |
17,2 |
10,0 |
12,0 |
17,4 |
21,2 |
24,4 |
(1) The speed of rotation depends on the available air pressure. The speed can be adjusted by means of a pressure regulator (available on request).
(2) Other possible materials on request (depending on the environment, the nature of the fluid and its characteristics if other than water).
(3) The temperature class depends on the temperature of the fluid in question.
(4) The provided sweeping diameters are valid for conventional rinsing operations. In cases where a finer cleaning is required, these diameters should be adapted.